logo
Found 90 products for "

flexible endoscope medical device repair training

"
Jakość MAJ-210 ZAWÓR DO BIOPSJI OLYMPUS DO ENDOSKOPU ELASTYCZNEGO fabryka

MAJ-210 ZAWÓR DO BIOPSJI OLYMPUS DO ENDOSKOPU ELASTYCZNEGO

MAJ-210 OLYMPUS BIOPSY VALVE FOR FLEXIBLE ENDOSCOPE ► Brief Description The Olympus MAJ-210 is a single-use, sterile biopsy valve designed for use with a range of Olympus endoscopes. It's a critical accessory for various endoscopic procedures. ► Features Instrument Access: Its primary function is to provide a sealed entry point for inserting and exchanging endoscopic instruments (such as biopsy forceps, snares, cytology brushes, or other therapeutic tools) through the

Jakość Szczotka czyszcząca Olympus Bw-20t do endoskopów giętkich fabryka

Szczotka czyszcząca Olympus Bw-20t do endoskopów giętkich

Olympus Bw-20t Cleaning Brush ► Brief Description The Olympus BW-20T is a widely used and essential reusable cleaning brush specifically designed for the manual cleaning of the instrument channels of Olympus flexible endoscopes. This brush plays a crucial role in the reprocessing of endoscopes to ensure patient safety and effective device function. ► Features Mechanical Cleaning of Instrument Channels: The primary function of the BW-20T is to mechanically scrub and remove

Jakość Flexible Endoscope Parts CCD driver board dla kolonoskopu PENTAX EC-3890LK fabryka

Flexible Endoscope Parts CCD driver board dla kolonoskopu PENTAX EC-3890LK

CCD Driver Board For PENTAX EC-3890LK Colonoscope ► Brief Description The CCD Driver Board for the PENTAX EC-3890LK is a critical internal electronic component located within the video colonoscope. Its primary role is to drive the Charge-Coupled Device (CCD) image sensor located at the distal tip of the endoscope. It manages the precise timing signals required to capture high-resolution medical images and prepares the raw video data for transmission back to the main PENTAX

Jakość Elastyczne części endoskopowe Pentax EG-27i10 Gastroskopowa tablica PCB tablica napędowa CCD fabryka

Elastyczne części endoskopowe Pentax EG-27i10 Gastroskopowa tablica PCB tablica napędowa CCD

Bending Rubber For Olympus CF-H290I Colonoscope ► Brief Description The CCD Driver Board for PENTAX EG-27i10 is a critical, high-precision electronic subassembly located within the connector or control body of the PENTAX i10-series video gastroscope. Acting as the primary hardware interface between the endoscope’s distal end Megapixel CCD (Charge-Coupled Device) sensor and the external video processor (such as the PENTAX EPK-i series), this board manages low-level timing,

Jakość Fiberoskop nosowo-gardłowo-krtaniowy Olympus ENF-GP do naprawy fabryka

Fiberoskop nosowo-gardłowo-krtaniowy Olympus ENF-GP do naprawy

Olympus ENF-GP fiber nasopharyngeal laryngoscope for repair ► Brief Description Fault: 1. Image with black point and image bundle broken 2. Light bundle aged 3. Insert tube aging and wrinkle 4. Bending section deformation 5. Angle with not enough 6. Rubber abrasion Solution: Replace image bundle; light bundle; insert tube; wires; helix tube; bending section; rubber ►Problem & Solutoin Brand Olympus Model ENF-GP Fault 1. Image with black point and image bundle broken 2. Light

Jakość OLYMPUS TJF-Q180V Elektroniczny dwunastokąt do naprawy fabryka

OLYMPUS TJF-Q180V Elektroniczny dwunastokąt do naprawy

OLYMPUS TJF-Q180V Electronic Duodenoscope For Repair ► Brief Description Inspection Results: 1. Image display is available; 2. The light bundle brightness is acceptable; 3. The insertion tube is worn; 4. The light guide tube is worn; 5. The angle is insufficient, the snake bone, steel wire and helix tube are worn; 6. The forceps elevator handle is damaged; 7. The handle shell is severely cracked. Solution: Replacement: Insertion tube, handle shell, light guide tube, snake

Jakość Toshiba PST-25BT Phased Array Probe do naprawy fabryka

Toshiba PST-25BT Phased Array Probe do naprawy

Toshiba PST-25BT Phased Array Probe For Repair ► Brief Description Fault: Housing break, image weak, crystal aging. Solution: Replace crystal and housing. ►Problem & Solutoin Brand Toshiba Model PST-25BT Fault Housing break, image weak, crystal aging Solution Replace crystal and housing ► Common issues with PST-25BT Phased Array Probe Image Quality Issues Cable and Connector Issues Probe Casing or Acoustic Lens Damage Temperature Abnormalities Host System Cannot Recognize

Jakość Sonda brzuszna Sonoscape C362 do naprawy fabryka

Sonda brzuszna Sonoscape C362 do naprawy

Sonoscape C362 Abdominal probe for repair ► Brief Description Fault: Cystal problem. Solution: Replace the Crystal. ►Problem & Solutoin Brand Sonoscape Model C362 Fault Cystal problem Solution Replace the crystal ► Common issues with C362 Probe Image Dropouts (Black Lines or Streaks) Damaged Lens Cracked Housing or Assembly Gaps Cable Issues Color Artifacts in the Image If your instrument has any of the above problems or others, please feel free to contact us for assistance.

Jakość 1898200T M4 Straightshot Microdebrider i rękojeść do naprawy fabryka

1898200T M4 Straightshot Microdebrider i rękojeść do naprawy

1898200T M4 Straightshot Microdebrider and Handpiece for repair ► Brief Description Fault: 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside is full of disinfection residue, motor corrosion. 3) The rotation direction of the knife head is stuck. 4) Handle paint off, internal corrosion.. Solution: Exchange the whole handpiece except cable. ►Problem & Solutoin Model 1898200T Fault 1) The bearing is corroded and the seal is broken. 2) Motor stuck, inside