Found 90 products for "

medical device repair training

"
Jakość Sonda wewnątrznaczyniowa Ultrasonix EC9-5/10 do naprawy fabryka

Sonda wewnątrznaczyniowa Ultrasonix EC9-5/10 do naprawy

Ultrasonix EC9-5/10 Endo-cavitary probe for repair ► Brief Description Fault: Bad array element. Solution: Replace crystal and housing. ►Problem & Solutoin BrandUltrasonix ModelEC9-5/10FaultBad array elementSolutionReplace crystal and housing ► Common issues with EC9-5/10 Probe Image Dropouts or ...

Jakość L12-3 Sonda ultradźwiękowa do naprawy fabryka

L12-3 Sonda ultradźwiękowa do naprawy

L12-3 Ultrasuound probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens. ►Problem & Solutoin Model L12-3 Fault Lens problem Solution Replace lens ► Common issues with L12-3 Probe Image Dropout: Shadows Dual Images Cable Jacket Damage Connector Damage Strain Relief ...

Jakość Hitachi C41V1 Sonda ultradźwiękowa do naprawy fabryka

Hitachi C41V1 Sonda ultradźwiękowa do naprawy

Hitachi C41V1 Ultrasuound probe for repair ► Brief Description Fault: Lens problem. Solution: Replace lens. ►Problem & Solutoin Brand Hitachi Model C41V1 Fault Lens problem Solution Replace lens ► Common issues with C41V1 Probe Image Dropouts or Streaks Cable and Connector Damage Acoustic Lens ...

Jakość STORZ 13820pks Gastroskop do naprawy fabryka

STORZ 13820pks Gastroskop do naprawy

STORZ 13820pks Gastroscope for Repair ► Brief Description Fault: 1.Rubber leakage; 2.Wire abrasion; 3. no up angle, other angle lack of. Solution: 1. Replace the wires, coil pipe, rubber; 2.Adjust angle. ►Problem & Solutoin Brand STORZ Model 13820pks Fault 1.Rubber leakage; 2.Wire abrasion; 3. no up ...

Jakość Olympus GIF-Q150 gastroskop do naprawy fabryka

Olympus GIF-Q150 gastroskop do naprawy

Olympus GIF-Q150 gastroscope for repair ► Brief Description Fault: 1.with image; 2.one eye of light bundle broken; 3.insert tube little aging; 4.biopsy tube abrasion; 5.bending section deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace light bundle ...

Jakość Endoskop Olympus TJF-160VR do naprawy fabryka

Endoskop Olympus TJF-160VR do naprawy

Olympus TJF-160VR endoscope for repair ► Brief Description Fault: 1.No image, CCD broken. 2. Light bundle broken completely. 3. Insert tube aging and wrinkle. 4. Biopsy tube broken. 5. Wires and helix tube broken. 6. clamp wires broken. 7. Operation part broken, no angle. 8. Grip broken. 9. The ...

Jakość Gastroskop Olympus GIF-H180J do naprawy fabryka

Gastroskop Olympus GIF-H180J do naprawy

Olympus GIF-H180J gastroscope for repair ► Brief Description Fault: 1.image with shadow; 2.light bundle broken; 3.insert tube with bite mark; 4.biopsy tube abrasion; 5.bending section serious deformation; 6.wires and helix tube abrasion; 7.light guide tube aging and wrinkle. Solution: Replace CCD, ...

Jakość Bronchoskop Olympus BF-XP160F do naprawy fabryka

Bronchoskop Olympus BF-XP160F do naprawy

Olympus BF-XP160F fiber scope for repair ► Brief Description Fault: 1. Image degumming, serious color, CCD aging, a few black and gray spots; 2. 20% of the light bundle is broken; 3. Insert tube aging slightly; 4. Biopsy tube wear, not smooth; 5. Bending section, steel wire, screw tube wear; ...

Jakość KARL STORZ 11278A1 ureteroskop do naprawy fabryka

KARL STORZ 11278A1 ureteroskop do naprawy

KARL STORZ 11278A1 ureteroscope for repair ► Brief Description Fault: 1) Image spotted with partially black point, image bundle aged 2) Light bundle partially wire broken 3) Insert tube aged 4) Biopsy tube abrasion and leakage 5) Wires and coil pipe abrasion Solution: Replace HD image bundle, light ...